Airflow: 150~500m³/h
Model: TFKC A2 series
1、Fresh air +Energy recovery
2、Airflow: 150-500 m³/h
3、Enthalpy exchange core
4、Filter: G4 primary filter+H12(can be customized)
5、Buckle type bottom maintenance easy replace filters
6、Customize as you want.
7、The up to 200pa static pressure design of the ERV fully guarantees the arrival of air volume even when the ground air supply.
• BLDC motor, more save energy
The high-efficiency brushless DC motor is built into the Smart energy recovery ventilator, which can reduce the power consumption by 70% and save energy significantly. VSD control is suitable for most engineering air volume and ESP requirements.
• The energy recovery core (enthalpy exchanger)
Featuring high moisture permeability, good air tightness, good tear resistance and aging resistance.The gaps between the fibers are so small that only water molecules with small diameters can pass through, not odor molecules with large diameters. In this way, temperature and humidity can be recovered smoothly, preventing pollutants from seeping into the fresh air.
• Energy saving principle
Heat recovery calculating equation:SA temp.=(RA temp.−OA temp.)×temp. recovery efficiency + OA temp.
Example:14.8℃=(20℃−0℃)×74%+0℃
Heat recovery calculating equation
SA temp.=(RA temp.−OA temp.)×temp. recovery efficiency + OA temp.
Example:27.8℃=(33℃−26℃)×74%
Air flow (m³/h) |
Energy recovery efficiency (%) | Electricity saving in summer (kW·h) |
Electricity saving in winter(kW·h) | Electricity saving in a year(kW·h) | Running costs saving(USD) |
250 | 60-76 | 1002.6 | 2341.3 | 3343.9 | 267.5 |
FRONT VIEW
SIDE VIEW
Model
|
A
|
B |
C |
D |
E |
F |
G |
H |
I |
d |
TFKC-015(A2series) |
660 |
690 |
710 |
635 |
465 |
830 |
190 |
200 |
420 |
114 |
TFKC-025(A2series) |
660 |
690 |
710 |
635 |
465 |
830 |
190 |
200 |
420 |
114 |
TFKC-030(A2series) |
735 |
735 |
680 |
785 |
500 |
875 |
245 |
250 |
445 |
144 |
TFKC-035(A2series) |
735 |
735 |
680 |
785 |
500 |
875 |
245 |
250 |
445 |
144 |
TFKC-050(A2series) |
860 |
735 |
910 |
675 |
600 |
895 |
240 |
270 |
540 |
194 |
Private Residence
Hotel
Basement
Apartment
Model |
Rated Airflow (m³/h) |
Rated E.S.P(Pa) |
Temp.Eff. (%) |
Noise (dB(A)) |
Purification efficiency |
Volt. (V/Hz) |
Power input (W) |
N.W(Kg) |
Size(mm) |
Control form |
Connect Size |
TFKC-015(A2-1D2) | 150 | 100(200) | 75-80 | 32 | 99% | 210-240/50 | 75 | 28 | 690*660*220 | Intelligent control/APP | φ110 |
TFKC-025(A2-1D2) | 250 | 100(160) | 73-81 | 36 | 210-240/50 | 90 | 28 | 690*660*220 | φ110 | ||
TFKC-030(A2-1D2) | 300 | 100(200) | 74~82 | 38 | 210-240/50 | 120 | 35 | 735*735*265 | Φ150 | ||
TFKC-035(A2-1D2) | 350 | 100(200) | 74-82 | 39 | 210-240/50 | 150 | 35 | 735*735*265 | φ150 | ||
TFKC-050(A2-1D2) | 500 | 100(200) | 76-84 | 42 | 210-240/50 | 220 | 41 | 735*860*285 | φ200 |
TFKC series air volume-static pressure curve
Air flow: 250m³/h
Running time of air conditioning system
Summer: 24h/day X 122days=2928(Jun. to Sep.)
Winter: 24h/day X 120days=2880(Nov. to Mar.)
Electric charge: 0.08USD/kW·h
Indoor conditions: Cooling 26℃(RH 50%), Heating 20C(RH50%)
Outdoor conditions: Cooling 33.2℃(RH 59%), Heating-10C(RH45%)
• Double purification protection:
Primary filter+ high efficiency filter can filter 0.3μm particles, and the filtration efficiency is as high as 99.9%.
G4*2(Default is white)+H12(Customizable)
A:Primary purification(G4):
The primary filter is suitable for the primary filtration of ventilation system, mainly used for filtering dust particles above.5μm; the primary filter can be reused after washing.
B: High efficiency purification(H12):
Effectively purify PM2.5 Particulate, for 0.1 micron and 0.3 micron particles, the purification efficiency reaches 99.998%. It traps 99.9% of bacteria and viruses and causes them to die from dehydration within 72 hours.
Tuya APP can be used for remote control.
App is available to IOS and Android phones with the following functions:
1. Monitoring indoor air quality Monitor local weather, temperature, humidity, CO2 concentration, VOC at your hand for healthy living.
2.Variable setting Timely switch, speed settings, bypass/timer/filter alarm/temperature setting.
3.Optional language Different language English/French/Italian/Spanish and so on to meet your requirement.
4.Group control One APP can control multiple units.
5.Optional PC centralized control(up to 128pcs ERV controlled by one Data acquisition unit)
Multiple data collectors are connected in parallel.